Violet vault · Neon-sealed drops · Free shipping over $75
Violet vault stack

XPS-BC (XPSBC1110) Condition:Very good Load cell resistance: > 40

SKU: 83789069552
4.4
EUR105.00 EUR149.00

Pay in 4 interest-free payments of $26.25 Learn more

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Sep 12 - Sep 17

Vault brief

Duotone panel — violet briefing on the left, lime-sealed detail sheet on the right.

Detail sheet
Description

Load cell resistance: > 40 Ω

Panel Type: UCP5

Power Supply: 9

mains protection with NC contact

The output voltage for signal "1" is a minimum of 2L+ (-1

XPS-BC (XPSBC1110) Condition:Very good Load cell resistance: > 40Manufacturer: Telemecanique Model: XPSBC1110 Series: Preventa safety technology Supply voltage: 24 V DC (20% +10%) Function: Two hand control monitoring Safety level: PL e Category 4 Outputs: Relay, 2 NO + 1 NC, potential free Power consumption: 6 VA Response time: max. 30 ms Mounting: 35 mm DIN rail Protection rating: IP20 (terminals), IP40 (housing) Temperature range: 10 C to +55 C Weight: approx. 0. 4 kg Certifications: TV, CSA, UL Indication: 3

Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

You may also like